ANALISIS RUGI DAYA DAN REKONSILIASI ENERGI JARINGAN DISTRIBUSI TEGANGAN MENENGAH 20 KV PADA PENYULANG NIJANG

Authors

  • Ahmad Jaya UNIVERSITAS TEKNOLOGI SUMBAWA
  • Wirentake UNIVERSITAS TEKNOLOGI SUMBAWA

DOI:

https://doi.org/10.36761/jt.v4i3.790

Keywords:

Susut/Rugi Daya, Penyulang Nijang, Rekonsiliasi Energi, Etap 12.6

Abstract

This study aims to determine the loss / power loss in the nijang feeder through the energy reconciliation process, simulation of the ETAP 12.6 program, and manual calculations. The benefits of this research can be used as a basis for consideration of the improvement efforts that should be carried out to minimize power losses in the medium voltage distribution network of Nijang feeders. The method used is quantitative research method because it takes data from the measurement of the transaction point which is then compared with the results in the simulation program ETAP 12.6 and manual calculations. The results showed that the power loss (kWh) resulted from 3 processes showed that the energy reconciliation process resulted in a greater power loss, namely 10,657 kWh, the ETAP 12.6 simulation resulted in a power loss of 3049 kWh and in manual calculations it resulted in losses. power of 4199 kWh, from the results of the research it can be seen that in the simulation process ETAP 12.6 and manual calculations only calculate power losses due to technical causes, while the energy reconciliation process includes technical and non-technical causes. It is hoped that this research can support efforts to improve power losses / losses in the PT PLN (Persero) UP3 Sumbawa environment.

References

REFERENSI

Amiruddin. (2010). Statistik Pendidikan.

Yogyakarta: Teras.

Binilang, R. B. (2017). Studi Analisa Rugi Daya

Pada Saluran Distribusi Primer 20 kV di

Kota Tahuna. E-Journal Teknik Elektro

dan Komputer vol. 6 no.2, 69.

Hutauruk, T. (1985). “Transmisi Daya Listrik”.

Jakarta: Erlangga.

Marniati, Y., & Hanifatulah, Q. A. (2018). Evaluasi

Susut Daya Penyulang Cendana 20 kV

pada Gardu Induk Bungaran dengan ETAP

6. Jurnal Teknik Elektro UTP, Vol. 7.

Pramono, T. J., Erlina, Soewono, S., & Fatimah.

(2018). Analisis Drop Tegangan Pada

Jaringan Tegangan Menengah Dengan

Menggunakan Simulasi Program ETAP.

Jurnal & Kelistrikan Vol. 10 No. 1, 26.

PT PLN (Persero). (1981). SPLN 41-8:1981.

Jakarta: PT PLN (Persero).

PT PLN (Persero). (1991). SPLN 87 :1991. Jakarta:

PT PLN (Persero).

PT PLN (Persero). (2010). Buku 1 Kriteria Disain

Enjinering Kontruksi Jaringan Distribusi

Tenaga Listrik. Jakarta Selatan: PT PLN

(Persero).

PT PLN (Persero). (2010). Buku 5 Standar

Kontruksi Jaringan Tegangan Menengah

Tenaga Listrik. Jakarta Selatan: PT PLN

(Persero).

PT PLN (Persero). (2018). Pedoman Teknis

Penerapan Formula Susut Jaringan

Tenaga Listrik di Lingkungan PT PLN

(Persero).

Purnomo, H. (2016). Analisis Sistem Daya I (Bagian

Saluran Transmisi Daya Elektrik).

Malang: Fakultas Teknik Universitas

Brawijaya.

Putranti, R. D. (2014). Perhitungan Kerugian Energi

Pada Penyulang Tambak Lorok - 03

Sebagai salah satu project Program Revass

(Revenue Assurance) dalam program

Rekonsiliasi Energi PT. PLN (Persero)

Area Semarang. Gema Teknologi Vol. 18

No. 1, 16.

Sugiyono. (2011). Metode Penelitian Kuantitatif,

kualitatif dan R & D. Bandung: Alfabeta.

Tanzeh, S. (2006). “Dasar-Dasar Penelitian”.

Surabaya: Lembaga Kajian Agama Dan

Filsafat (eLKAF).

Tenda, N. (2016). Penyusutan Daya Listrik Pada

Penyulang Jaringan Transmisi Isimu

Marisa. E-Journal Teknik Elektro dan

Komputer vol. 5 no. 1, 75.

Published

2020-10-15

Issue

Section

Articles