ENERGY AUDIT ON THE ORANGE BUILDING AND THE ORANGE BACK BUILDING FACULTY OF ECONOMICS AND BUSINESS AT THE UNIVERSITY OF TECHNOLOGY SUMBAWA
DOI:
https://doi.org/10.51401/altron.v1i1.3293Keywords:
Analysis, Energy Audit, Building Faculty Economics and Business (FEB) University Sumbawa Technology.Abstract
Energy electricity drier Now become need tree for human. Supply energy standard electricity _ And each other related is strict conditions _ And must fulfil achievement objective development. University Sumbawa Technology (UTS) as Wrong One consumer energy electricity presumably need energy audit _ For save cost usage electricity, wrong one in the building Orange and Building Behind Orange (GBO). To know is consumption electricity Already fulfil level efficient or no, then from That need exists analysis opportunity to save electricity through energy audits. From the results obtained through the methods of measurement, processing, analysis and observation, the energy consumption intensity values (IKE) of the Orange Building and the Orange Rear Building in general are . With the IKE value for air-conditioned rooms, the average value is 7.07660456 kWh/m 2 / month and for non-AC rooms, the average value is 6.860981861 kWh / m 2 / month. Broadly speaking, from the rooms in the Orange Building and the Orange Back Building, it can be concluded that the categories are very efficient to efficient, but several rooms are still categorized as wasteful, namely the GO 2 room with an IKE value of 18.992 kWh/m 2 / month, and canteen room 20.73059361 kWh/m 2 / month. Until it is necessary to carry out savings opportunities. For rooms that are categorized as wasteful, it can be concluded that energy saving opportunities can be carried out by: Reducing power consumption operations, such as power consumption and hours of use.
References
M. Suwargina, “Audit Energi Pada Bangunan Gedung DPRD Kabupaten Sleman,” Vol. 11, No. 2, Pp. 179–184, 2017.
D. Almanda and K. Bayu, “Audit Energi Listrik Pabrik,” Resistor (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer), vol. 1, no. 1, pp. 27–36, 2018.
M. Ikhsan and M. Saputra, “Audit Energi Sebagai Upaya Proses Efisiensi Pemakaian Energi Listrik Di Kampus Universitas Teuku Umar ( UTU ) Meulaboh,” Jurnal Mekanova, vol. 2, no. 3, pp. 136–146, 2016.
F. Irawati and F. D. Kartikasari, “Studi Konsumsi Energi di Kantin Keluwih Universitas Surabaya,” KELUWIH: Jurnal Sains dan Teknologi, vol. 2, no. 2, pp. 81–85, 2021, doi: 10.24123/saintek.v2i2.4042.
P. Studi, P. Teknik, and E. Fptk, “Analisis Audit Energi untuk Pencapaian Efisiensi Penggunaan Energi di Gedung JICA FPMIPA Universitas Pendidikan Indonesia,” Electrans, vol. 12, no. 1, pp. 81–88, 2013.
J. Custer, “Analisis Audit Energi Di Bengkel Las Politeknik Negeri Bengkalis,” Prosiding Seminar Nasional Pakar, pp. 53–58, 2018, doi: 10.25105/pakar.v0i0.2603.
A. Biantoro, Wahyudi and D. S. Permana, “Analisis Audit Energi Untuk Pencapaian Energi Di Gedung Ab, Kabupaten Tangerang, Banten,” Jurnal Teknik Mesin (JTM), vol. 6, pp. 1–9, 2017.
V. C. P. Glori Valentino Jr Agus, Meita Rumbayan, “Analisis Audit Energi Hotel Sintesa Peninsula Manado,” Jurnal Teknik Elektro dan Komputer, vol. 8, no. 3, p. 7, 2019.
A. Wahid, Ms. Ir. Junaidi, and M. Dr. Ir. H. M. Iqbal Arsyad, “Analisis Kapasitas Dan Kebutuhan Daya Listrik Untuk Menghemat Penggunaan Energi Listrik Di Fakultas Teknik Universitas Tanjungpura,” Jurnal Teknik Elektro UNTAN, vol. 2, no. 1, p. 10, 2014.
U. M. Sugeng and A. P. Agung, “Sistem Tata Udara Di Gedung Mina Bahari III Kantor Pusat Kementerian Kelautan Dan,” vol. 23, no. 2, pp. 51–59, 2021.
A. W. Tanod, I. H. Tumaliang, and L. S. Patras, “Konservasi Energi Listrik di Hotel Santika Palu,” E-journal Teknik Elektro dan Komputer, vol. 4, no. 4, pp. 46–56, 2015.
A. Pramudhita and R. Hermawan, “Perancangan Sistem Tata Udara Pada Ruang Nicu Di Lantai 3 Rumah,” JTT (Jurnal Teknologi Terapan), vol. 6, no. 2, pp. 125–135, 2020.
A. Fleta, “Analisis pencahayaan alami dan buatan pada ruang kantor terhadap kenyamanan visual pengguna,” JURNAL PATRA, vol. 3, no. 1, pp. 33–42, 2021.
asrul Azmi, “Studi Perencanaan Kebutuhan Instalasi Listrik Di Rumah Sakit Bersalin Jeumpa,” pp. 1–8, 2019.
“SNI_2011_audit_energi_pada_bangunan_gedung.”
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Habil Bil, Nova Ariyanto, Indra Darmawan , Paris Ali Topan

This work is licensed under a Creative Commons Attribution 4.0 International License.